ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
5-8
TABLE 5-1. DIRECT SUPPORT TROUBLESHOOTING (CONTINUED)
Not OK
Not OK
OK
OK
GENERATOR SET FAILS TO GENERATE
SUFFICIENT VOLTAGE
Generator set fails to generate
sufficient voltage.
Check for low engine
speed. Refer to
TM 9-2815-259-24.
Refer to TM
9-2815-259-24.
Test generator main
stator (see para. 5.10.7).
Replace defective components.
Test power potential
transformer (see para. 5.8.6).
Replace power potential
transformer (see para.
5.8.6).
Not OK