ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-3
(3)
Fill radiator with proper coolant/antifreeze in accordance with Table 4-1. Fill radiator to a level two
inches below fill opening.
TABLE 4-1. COOLANT
AMBIENT
TEMPERATURE
RADIATOR
COOLANT
RATIO
+40°F TO +120°F
(4°C TO 49°C)
WATER: MIL-A-53009
INHIBITOR, CORROSION
35:1
-25°F TO +120°F
(-32°C TO +49°C)
ANTIFREEZE, MULTI ENGINE TYPE
Commercial Item Description (CID) A-A-52624
Type IP, Ethylene Glycol Base
N/A
-25°F TO +120°F
(-32°C TO +49°C)
MIL-A-11755
ANTIFREEZE
N/A
(4)
Remove cap from overflow bottle.
(5)
Fill overflow bottle to COLD level mark.
(6)
Install caps on overflow bottle and radiator.
(7)
After 30 minutes of operation, check coolant/antifreeze level at overflow bottle. Add
coolant/antifreeze to overflow bottle as required.
c. Fuel Tank.
__________
WARNING
Fuels used in the generator set are flammable. Do not smoke or use open
flames when performing maintenance. Failure to comply can result in flames
and possible explosion and can cause injury or death to personnel and damage
to the generator set.
(1)
Check that fuel drain valve (1, Figure 4-1) is closed.
__________
WARNING
Hot engine surfaces and sparks from the engine and generator circuitry are
possible sources of ignition. When hot refueling with DF-1, DF-2, DF-A, JP5
or JP8, avoid fuel splash and fuel spill. Do not smoke or use open flame when
performing refueling. Failure to comply can result in flames and possible
explosion and can cause injury or death to personnel and damage to the
generator set.
(2)
Remove fuel tank filler cap (located on the left side of the generator set housing).