ARMY TM 9-6115-670-14&P
G-1
APPENDIX G
OPERATOR'S LUBRICATION INSTRUCTIONS
G-1. SCOPE.
This appendix provides lubrication instructions for the Auxiliary Power Unit 10 kW, 120/240 VAC,
60 Hz (APU).
G-2. OPERATOR'S LUBRICATION INSTRUCTIONS.
The APU's engine oil level shall be checked on a daily basis (para 3.1.). Engine oil shall be replenished
as needed. Engine oil shall be changed every 100 hours of operation (para 4.14.).
G-2.1. Oil Filter Replacement. The oil filter shall be replaced at the following intervals:
a.
With every oil change (each 100 hours of operation) (para 4.15.).
b.
When it is known to be contaminated or clogged.
G-2.2. Army Oil Analysis Program. The APU is not enrolled in the Army Oil Analysis Program.
HARDTIME INTERVALS APPLY.
G-2.3. Warranty Hardtime Statement. For equipment under manufacturer's warranty, hardtime oil
service intervals shall be followed. Intervals shall be shortened if lubricants are known to be
contaminated or if operation is under adverse conditions (such as longer than usual operating hours,
extended idling periods, and extreme dust).
G-2.4. Corrosion Prevention Control (CPC). Refer to Chapter 1 of this technical manual (TM) for
CPC instructions.
G-3. LUBRICANT TABLE.
Table G-1 identifies lubricants and the ambient temperatures they should be used in.
G-4. EXPLANATION OF COLUMNS.
The following provides an explanation of columns found in the tabular listings:
a. Column 1, Temperature Range. Identifies temperature range that lubricant should be used in.
b. Column 2, Lubricant Mil Symbol Specification. Identifies the military specification for each
lubricant.
c. Column 3, Capacity. Specifies the amount of lubricant in quarts (qt.) and liters (l) to be used
with each oil change.