TM 9-6115-689-13&P
Section I. OPERATOR LUBRICATION
3.1 GENERAL.
Lubricate the Electric Power Plant III at regular intervals as indicated in figure 3-1.
Item
No.
1
2
3
4
Control cable drum, inner surfaces
5
Power cable drums, inner surfaces
6
N.I.
N.I.
7
8
Item Name
Gen Set 1 and 2, groundind strap screw
PDU grounding bar, grounding strap screws
Pallet frame, grounding strap screw
Lubricate with
Terminal grease (item 4, Appendix E)
Terminal grease (item 4, Appendix E)
Terminal grease (item 4, Appendix E)
Lubricating grease (item 1, Appendix E)
Lubricating grease (item 1, Appendix E)
Power cable drums, swinging device grease nipple
Lubricating grease (item 1, Appendix E)
All threaded and plug connections
Copper paste (item 5, Appendix E)
All bolt/spring pin connections
Lubricating grease (item 1, Appendix E)
Storage box hinge
Lubricating grease (item 1, Appendix E)
Swing arm grease nipple
Swing arm pin
Lubricating grease. (item 1, Appendix E)
Lubricating grease (item 1, Appendix E)
9
3-2