ARMY TM 9-6115-645-24
AIR FORCE TO 35C2-3-444-12
MARlNE CORPS TM 09244A/09245A-24/2
NOTES:
1. Refer to TM 9-6115-645-24P for materials required.
PROCEDURES:
1. Position 0.75 inch of insulation sleeving (2) on each lead of diode (1), leaving 0.25 inch of bare wire on each lead. Shrink
sleeving to ft.
2. Crimp and solder terminals (3) on end of each diode (1) lead.
FIGURE D-9. Diode Assembly (P/N: 88-2241 8-2)
D-9