ARMY TM 9-6115-645-10
AIR FORCE TO 35C2-3-444-11
MARINE CORPS TM 09244A/09245A-10/1
c.
d.
e.
f.
g.
h.
i.
Keep all access doors
closed, as much as
possible, to prevent
entry of dust and sand
into housing assembly.
Wipe dust and sand
frequently from the
generator set external
surface and
components.
Wash
exterior surfaces
frequently with clean
water when generator
set is not operating.
Semite engine air
cleaner assembly
frequently to
compensate for intake
of additional dust or
sand.
Drain sediment
frequently from fuel
filter/water
separator.
When
servicing fuel tank be
careful to prevent
dust or sand from
entering fuel tank.
Change engine oil and
oil filter frequently.
Store oil and fuel in
dust-free containers.
Ensure that generator
set ground connections
are free of dust and
sand and connections
are tight before
starting the unit.
2-16
OPERATION UNDER RAINY OR
HUMID CONDITIONS .
CAUTION
Failure to remove
waterproof material
before operating
generator set could
result in equipment
damage.
a.
b.
c.
d.
If possible, provide a
shelter for generator
set.
Cover generator
set with canvas or
other waterproof
material when it is
not being operated.
Provide adequate
drainage to prevent
water from
accumulating on
operation site.
Keep all generator set
access doors closed,
as much as possible,
to prevent entry of
water into housing
assembly.
Drain water frequently
from fuel filter/water
separator.
DC voltages are
present at generator
set electrical
components even with
generator set shut-
down .
Avoid
grounding yourself
when touching elec-
trical components.
Failure to follow
this warning can
result in personal
injury.
2-38