ARMY TM 9-6115-644-24
AIR FORCE TO 35C2-3-446-12
MARINE CORPS TM 09249A/09246A-24/2
2-36-1
a.
b.
2-36-2
a.
b.
c.
d.
e.
f.
i.
j.
k.
1.
2-36-3
a.
b.
c.
d.
e.
f.
2-36-4
a.
b.
c.
d.
e.
lnspection.
Shut down generator set.
Inspect switch for loose connections and mounting, and other damage.
Testing.
Shut down generator set.
Open battery access door and disconnect negative battery cable.
Release control panel by turning two fasteners and lower control panel slowly.
Tag and disconnect BATTLE SHORT switch (23, FIGURE 2-13) electrical leads.
Place switch in ON position.
NOTE
Refer to Wiring Diagram FO-2 for terminal positions.
Set multimeter for ohms and check for continuity between terminals 2 and 3,5 and 6,8 and 9, and 11 and 12.
Place switch in OFF position.
Check for continuity between terminals 1 and 2, 4 and 5, 7 and 8, and 10 and 11.
Replace switch if any open circuit is indicated.
Connect electrical leads to switch (23) and remove tags.
Raise and secure control panel.
Connect negative battery cable and close battery access door.
Removal.
Shut down generator set.
Open battery access door and disconnect negative battery cable.
Release control panel by turning two fasteners and lower control panel slowly.
Tag and disconnect BATTLE SHORT switch (23, FIGURE 2-13) electrical leads.
Remove nut (20), washer (21), and protective cover (22).
Remove BATTLE SHORT switch (23) from control panel and tab washer (24) from switch stem.
Installation.
Install tab washer (24, FIGURE 2-13) and insert BATTLE SHORT switch (23) into control panel.
Install protective cover (22), washer (21), and nut (20).
Connect electrical leads and remove tags.
Raise and secure control panel.
Connect negative battery cable. Close battery access door.
2 - 7 0