ARMY TM 9-6115-641-24
AIR FORCE TO 35C2-3-456-12
Table 1-1. Tabulated Data
1 Generator Set:
a. National Stock Number
b. Overall Length
c. Overall Width
d. Overall Height
e. Dry Weight (less Basic
Issue Items List)
f.
Wet Weight
2 Engine:
a.
b.
c.
d.
e.
f.
g.
h.
Manufacturer
Model
Type
Displacement
Altitude Degradation,
4000 ft. (1220 m) to
8000 ft. (2440 m)
Firing Order
Cold Weather Starting
Aid System Use
Valve Tappet Clearance
Adjustment:
3 Cooling System:
a.
Type
b. Capacity
c.
Normal Operating
Temperature
d. Temperature Indicating
System Voltage Rating
4 Lubricating System:
a.
Type
b. Oil Pump Type
c.
Normal Operating
Pressure
d. Oil Filter Type
e. Capacity
f.
Pressure Indicating
System Voltage Rating
MEP-802A
6115-01-274-7387
50.6 in. (128.6 cm)
32 in. (81 .28 cm)
37 in. (93.98 cm)
800 lb (362.8 kg)
868 lb (393.7 kg)
Onan
DN2M
Two cylinder, four cycle, naturally
aspirated diesel
57 cu in. (0.9 liters)
3.5% per 1000 ft (305 m)
1,2
40°F (4°C) to 25°F (32°C)
None Required
Pressurized radiator and pump
6.2 qts (5.9 liters)
170-200°F (7793°C)
24 VDC
Full flow, circulating pressure
Positive displacement gear
25-60 psi (172-414 kPa)
Full flow, spin-on replacement
element
3.2 qts (3.0 liters)
24 VDC
MEP-812A
6115-01-274-7391
50.6 in. (128.6 cm)
32 in. (81 .28 cm)
37 in. (93.98 cm)
825 lb (374.2 kg)
678 lb (398.2 kg)
Onan
DN2M
Two cylinder, four cycle, naturally
aspirated diesel
57 cu in. (0.9 liters)
3.5% per 1000 ft (305 m)
1, 2
40°F (4°C) to 25°F (32°C)
None Required
Pressurized radiator and pump
6.2 qts (5.9 liters)
170-200°F (7793°C)
24 VDC
Full flow, circulating pressure
Positive displacement gear
25-60 psi (172-414 kPa)
Full flow, spin-on replacement
element
3.2 qts (3.0 liters)
24 VDC
1-4