TM 5-6115-628-14&P
1-8. Administrative Storage.
a. Army equipment placed in administrative storage will have preventive maintenance performed
in accordance with the PMCS tables before storage. When equipment is removed from stor-
age, PMCS will be performed to ensure operational readiness.
b. (F) For administrative storage procedures for Air Force equipment, refer to TO 35-1-4, Pro-
cessing and Inspection of Aerospace Ground Equipment for Storage and Shipment.
1-9.
Preparation for Shipment and Storage.
a. (A) Army - Refer to TB 740-97-2.
b. (F) Air Force - Refer to TO 35-1-4 for component of end item generator sets and TO 38-1-5
for installed engine.
Section Il. DESCRIPTION AND DATA
1-10.
Description. Power Plant AN/MJQ-15 is made up of two PU-732/M power units. Each power
unit is, in turn, made up of one Tactical Precise Generator Set, DOD Model MEP-113A mounted on a
modified M200A1 trailer. These generator sets are liquid-cooled, diesel engine-driven units, each
with a load capacity of 15 KW at 400 Hz. The trailers are two-wheeled units with dual tires mounted.
Each trailer has a 2 1/2-ton carrying capacity. The modifications to the basic trailers provide stowage
for the accessories and all equipment necessary for mobile operation as well as providing a work plat-
form for the operator and maintenance personnel. Output from the power plant is applied to the system
or equipment being powered through a switch box. Figures 1-1 and 1-2 illustrate the power plant.
1-11.
Tabulated Data. The tabulated data provides operator and unit level personnel with the
dimensions and weights for Power Plant, AN/MJQ-15. These specifications are computed from the
combined dimensions and weights of the two power units that make up the power plant. Specifications
for a single PU-732/M power unit can be found in TM 5-6115-594-14&P. For additional information
concerning Generator Set DOD Model MEP-113A, refer to TM 5-6115-464-12, - 34, and - 24P. For
additional information on the M200A1 trailer, refer to TM 9-2330-205-14&P. The tabulated data also
includes the location and content of all data plates unique to the power plant.
a. Identification, Information, and Warning Plates.
(1) Modification identification plate.
(a) Location. This plate is located on front roadside frame between the trailer body and
Iunette.
(b) Content.
MODIFIED FOR POWER PLANT AN/MJQ-15
NSN 6115-00-400-7591
UNIT A (or B, as applicable)
1-2