LO 9-6115-642-12
LUBRICATION ORDER
LI-09247A/09248A-12
Clean parts in a well-ventilated area. Avoid inhalation of solvent fumes and prolonged exposure
of skin to cleaning solvent. Wash exposed skin thoroughly. Dry Cleaning solvent (Fed. Spec.
PD-680) used to clean parts is potentially dangerous to personnel and property. Do not use near
open flame or excessive heat. Flash point of solvent is 100F to 138F (38C to 59C).
Use care when removing oil fill cap to prevent loss of cap gasket. Gasket may be lost and drop
out when cap is removed.
FOR OPERATION OF EQUIPMENT IN COLD TEMPERATURES BELOW -10F (-23C). Remove lubricants
1.
prescribed in the key for temperatures above -10F (-23C). Clean parts with dry cleaning solvent, PD-680
Type II or equivalent. Relubricate with lubricants specified in the key for temperatures 0F to -65F (-17C
to -53C).
2 . OIL FILTER. After installing filter, fill crankcase, operate engine 5 minutes, and check housing for leaks.
Shut down engine, check crankcase oil level, and bring to full mark. Oil filter replacement interval shall align
with on-condition, AOAP analysis or hard time oil change requirements.
OIL CAN POINTS. Every 100 hours, lubricate the door hinges, latches, control linkage, and all exposed
3.
adjusting threads with OE/HDO/OEA.
The dipstick is marked so that the crankcase oil can be checked while engine is stopped.
4.
Fill and check oil level. After checking level, place dipstick into the adapter tube to prevent oil leakage or
LUBRICANTS. The
following is a
list of
lubricants with the military symbols and applicable military
5.
specification numbers:
OE/HDO
- MIL-L-2104
OEA
- MIL-L-46147
Copy of this Lubrication Order will remain with
the equipment at all times.
Instructions
contained herein are mandatory.
Card 3 of 4