TM 9-6115-730-24
0013
ELECTRONIC TECHNICIAN (ET) TROUBLESHOOTING - Continued
CORRECTIVE ACTION - Continued
STEP 10.
Disconnect wires from terminals 19 and 20 on LSM A4.
STEP 11.
Select CONTINUE on the Cat ET. Wait until the Cat ET indicates that the timing
is calibrated.
STEP 12.
On EMCP, set ENGINE CONTROL switch to OFF/RESET. Set Battery
Disconnect Switch to OFF. Set DEAD CRANK SWITCH to OFF.
NOTE
Disconnect the 7X-1695 Cable Assembly before exiting the TIMING CALIBRATION screen to
prevent diagnostic codes from activating.
STEP 13.
Disconnect the 7X-1695 cable assembly.
STEP 14.
STEP 15.
On the EMCP, set the ENGINE CONTROL switch to OFF/RESET.
STEP 16.
Remove the 6V-2197 transducer and the 7X-1171 transducer adapter.
STEP 17.
Reinstall the timing calibration plug.
STEP 18.
Verify the problem has been resolved.
0013-30