TM 9-6115-730-10
200 kW TACTICAL QUIET GENERATOR SET
0012 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION
INSTRUCTIONS Continued
Table 1. Preventive Maintenance Checks and Services Continued.
LOCATION/
NOT FULLY
ITEM
ITEM TO
MISSION
NO.
INTERVAL
CHECK/SERVICE
PROCEDURE
CAPABLE IF:
_________
30
Before
Ground Rod Cable
WARNING
and Connection
High voltage is produced when this
generator set is in operation. Make sure
unit is completely shut down and free of
any power source before attempting any
repair or maintenance on the unit.
Failure to comply can cause injury or
death to personnel.
Inspect ground rod, grounding cable to
Any missing or
trailer terminal, and grounding cable to
damaged parts.
Connections are loose
breaks, damage and corrosion.
or corroded.
31
Before
Accessory Box
Inspect accessory box clamping hatch hasp
and rivets for rust, corrosion and wear.
Check accessory box contents to ensure that
Ground rod and
all required items are present and
components are
serviceable.
missing pr
unserviceable.
WINTERIZATION
KIT
_________
32
Before
Fuel lines
WARNING
flammable. Do not smoke or use open
flames when performing maintenance.
Failure to comply can result in flames
and possible explosion and can cause
injury or death to personnel and
damage to the generator set.
Open battery access doors and inspect fuel
Any fuel leaks,
lines to fuel-fired heater for leaks,
damaged, loose, or
damaged, loose or missing parts.
missing parts.
Check hoses for leaks or cracks.
33
Before
Coolant hoses
Class III leaks.
Verify that coolant shutoff valves on engine
34
Before
Coolant shutoff
Shutoff valves are not
are secure.
valves
secure.
0012 00-10