TM 9-6115-729-24
0054
REMOVAL
NOTE
Table 1 identifies removal and installation steps for maintenance significant components of the
electrical installation. Cut tiedown straps as required.
FIGURE 1
REMOVAL
INSTALLATION
NAME
ITEM
STEP
STEP
DEAD CRANK SWITCH
1
1 thru 3
15
CATSW1 (RESET SW FUEL)
18
1, 2, and 6
12
CATSW2 (RESET SW OIL)
19
1, 2, and 6
12
22
1, 2, and 7
11
Starter motor magnetic switch (SMMS) relay
22
1, 2, and 8
10
Circuit breaker CB2
48
1, 2, and 13
4
Circuit breaker CB4
52
1, 2, and 14
3
Circuit breaker CB5
47
1, 2, and 13
4
40
1, 2, and 11
6
42
1, 2, and 12
5
Fuses F1, F2, and F3
30
1, 2, and 9
9
1. Ensure generator set is fully stopped, ENGINE CONTROL switch is OFF/RESET, Battery Disconnect Switch is
OFF, and DEAD CRANK SWITCH is OFF before proceeding.
2. Open right rear doors and left rear doors.
3. To remove DEAD CRANK SWITCH (Figure 1, Sheet 1, Item 1), tag and disconnect wires from switch, remove
nut (Figure 1, Sheet 1, Item 2), lockwasher (Figure 1, Sheet 1, Item 3), and switch.
4. If necessary, drill out two rivets (Figure 1, Sheet 1, Item 4) and remove dead crank plate (Figure 1, Sheet 1,
Item 5). Remove two locknuts (Figure 1, Sheet 1, Item 6), lockwashers (Figure 1, Sheet 1, Item 7), washers
(Figure 1, Sheet 1, Item 8), screws (Figure 1, Sheet 1, Item 9), and switch plate (Figure 1, Sheet 1, Item 10)
from air cleaner bracket (Figure 1, Sheet 1, Item 11).