TM 9-6115-729-10
0012 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION
INSTRUCTIONS Continued
Table 1. Preventive Maintenance Checks and Services Continued.
LOCATION/
NOT FULLY
ITEM TO
MISSION
ITEM
NO.
INTERVAL
CHECK/SERVICE
PROCEDURE
CAPABLE IF:
4
Before
Skid Base
Inspect skid base for cracks or corrosion,
Skid base is cracked
missing or damaged lift rings, or other
or shows signs of
damage.
structural damage or
lifting rings are
missing or
damaged.
5
Before
Acoustical Materials
Ensure acoustical materials are securely in
place, free of damage or not missing.
ENGINE
COMPARTMENT
__________
6
Before
Engine Assembly
WARNING
DC voltages are present at generator set
electrical components even with
generator set shut down. Avoid
shorting any positive with ground/
negative. Failure to comply can cause
injury to personnel and damage to
equipment.
Hardware is loose,
Check for loose, damaged, or missing
damaged, or
hardware.
missing.
__________
7
Before
Fuel System
WARNING
flammable. Do not smoke or use open
flames when performing maintenance.
Failure to comply can result in flames
and possible explosion and can cause
injury or death to personnel and
damage to the generator set.
Inspect fuel system for leaks, damaged,
Any fuel leaks,
loose or missing parts.
damaged, loose, or
If using auxiliary fuel source, check for
missing parts.
leaks, damaged, loose or missing parts.
8
Before
Fuel Filter/Water
Inspect fuel filter/water separator for leaks,
Any fuel leaks,
Separator
proper mounting, cracks, damage, or
cracks, or missing
missing parts.
parts.
0012 00-5