ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
(2) Release instrument panel by turning fastener, open instrument panel slowly.
(3) If replacing terminal board remove and retain discharge varistor, refer to paragraph
4.36.c.
(4) Tag and disconnect electrical leads from terminal board (Figure 4-38).
(5) Tag and remove bus (MEP-531A) from terminal board.
(6) Remove screws, lockwashers, washers, and terminal board from control panel.
c.
Testing.
Replace terminal board if any terminal sets indicate an open circuit.
)
(