ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
WARNING
Note the orientation of the load terminals before removing
them. They must be installed in exactly the same way to
preclude the possibility of accidental contact with the lug cover
and the potential for electrical shock resulting from this contact.
(7) Hold terminal body hex with wrench and remove nuts, washers, and load terminals
from load terminal board.
c.
Installation.
WARNING
Be sure the load terminal retaining clip is closed to prevent
contact with the lug cover as electrical shock could occur.
(1) Install load terminals (Figure 4-37) in load terminal board. Then hold terminal body
hex with wrench and install washers and nuts.
(2) Position transient suppressor assembly and electrical leads on load terminals and
secure with washers, nuts, and locknuts. Remove tags.
(3) Close and secure instrument panel.
(4) Connect load cables to load terminals as necessary.
(5) Close and secure lug cover.
TERMINAL BOARD.
a.
Inspection.
NOTE
Terminal board numbering runs from left to right starting with number 1.
(2) Release instrument panel by turning fastener, open instrument panel slowly.
(3) Visually inspect terminal board for security, cracks, broken jumpers, corrosion, and
other damage.
(4) Close and secure instrument panel.
b.
Removal.