ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
DISCHARGE VARISTOR.
a.
Inspection.
(2) Release instrument panel by turning fastener, open instrument panel slowly.
(3) Visually inspect the discharge varistor for security, cracks, broken wires, corrosion,
and other damage.
(4) Close and secure instrument panel.
b.
Testing.
(3) Replace discharge varistor if continuity is indicated in either direction.
(4) Install disconnected lead of discharge varistor.
c.
Removal.
(2) Release instrument panel by turning fastener, open instrument panel slowly.
(3) Tag electrical leads for discharge varistor (Figure 4-35) at terminals 5 and 6 of TB1
(MEP-531A) or terminals 6 and 7 of TB1 (MEP-501A).
(4) Remove screws and discharge varistor from control panel.
d.
Installation.
(1) Install discharge varistor (Figure 4-35) in control panel with screws.
(2) Remove tags from electrical leads.