ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
BEARING
BRUSH
BRACKET
CAP
WIRE
SCREW
GUARD
LOCKWASHER
CAP
SCREW
(4) Tag stator wires and brush wires connected by screws.
(5) Remove screws and brush wires, and disconnect stator wires from bearing bracket.
(6) Unscrew brush caps and lift brushes out gently.
b.
Inspection.
(1) Inspect brush wires for security of terminals, cracked insulation, and other damage.
(2) Inspect brush caps for cracks and stripped threads.
(3) Measure brush length [0.875-0.50 in. (2.2-1.3 cm)].
(4) Replace damaged or worn parts.
c.
Installation.
NOTE
Always replace brushes in sets.
(1) Insert brushes in bearing bracket and secure with brush caps.
(2) Connect stator wires and brush wires with screws. Remove tags.
Cross tighten
capscrews to 6 lbs-ft (8.2 Nm).