TM 9-6115-669-13&P
Visually inspect electronic module Al (8) assembly for broken wires and discoloration due to
excessive heat.
a
Using multimeter check continuity resistance for each diode V12 to V19 (5) without removing
diodes. Resistance must be infinity in reverse direction, and less than 0.3 Ohm in forward
direction.
b.
Check shorting jumpers (6, 7) between terminals 9/11 and 13/15.
a
Pull off cover (4).
b.
Unsolder diodes V12 to V19 (5). Record the positions.
c.
Solder new diodes V12 to V19 (5).
d. Install cover (4).
a.
Push in tab on bottom of electronic module A1 (8) and set on mounting bar.
b.
Install cables on electronic module A1 (8).
c.
Install cables 116, 117, and 118 on contactor K3. Refer to paragraph 5.10.
d. Remove stanchion.
e.
Stow prop (3), close access door (2) and secure..
f.
Install stanchion by PDU (1).