TM 5-6115-625-14&P
Table 3-2. Operator/Crew Preventive Maintenance Checks and Services (PMCS) CONT.
B - B e f o re
D During
A A f t er
W - W e e k l y
M M o n t h ly
I t em
no.
21
2
2
2
3
24
3-16
Interval
Item to be inspected.
Procedure: check for and
have repaired, filled, or
adjusted as needed
BATTLE SHORT INDICATOR LIGHT
Push in on lens housing. Light (30) should
illuminate. If not, replace bulb.
CIRCUIT BREAKER INDICATOR LIGHT
Push in on lens housing. Light (31) should
illuminate. If not, replace bulb.
BRAKE DRUMS AND HUBS
W A R N I NG
A defect in the operation of the
brake or hub can cause these
parts to get hot enough to cause
serious burns. Use extreme cau-
tion when attempting to detect
heat in this area.
Feel drums and hubs for overheating to
detect dragging or binding.
AIR RESERVOIR
Open draincock (32) to drain moisture from
air reservoir (33) and close when finished.
Equipment is not
ready/available if:
Brakes or hub are
dragging or binding.