TM 3-1040-280-20&P
2-5.
INSTALLATION INSTRUCTIONS (CONT).
f. Generator and Bracket (Cont).
INSTALLATION (CONT)
a.
Remove two screws (6), four washers (7), two connecting links (8), two lockwashers (9), and two nuts (10) from
each generator bracket (1).
WARNING
Generator is heavy. To prevent personnel injury, use a hoist or four people to lift.
b.
Position smoke generator (11) in bracket (1) with generator frame (12) under lips (13) on bracket and against
stop blocks (14).
c.
Secure smoke generator (11) in bracket (1) with two screws (6), four washers (7), two connecting links (8), two
lockwashers (9) and two nuts (10).
Change 1 2-8